Antminer Hydro Cooling Rack 9-Slot 50kW

The Hydro Cooling Rack 9-Slot cools up to 9 Antminer S19/S21/S23 Hydro units with 50 kW of capacity in an 800 × 800 mm footprint. The compact professional choice for home and garage mining — available in cooling or heat-recovery heating versions.

  • Capacity: 9 Antminer Hydro units at full load
  • Cooling power: 50 kW with matching outdoor dry cooler
  • Versions: Cooling or heating (heat recovery) configuration
  • Protection: Per-miner safety switches, color-coded inlet/outlet connections
  • Dimensions: 800 × 800 × 1,600 mm, 155 kg, −25°C ~ 45°C ambient, in stock

Price range: $2,380.00 through $3,250.00

Not Fitting Your Site?

Tell us your mining capacity and site requirements, and we’ll recommend the right hydro-cooling container for your deployment.

Facebook
Twitter
LinkedIn
Pinterest
VK
Reddit

Hydro Cooling Rack 9-Slot 50kW – Now Available

CONTAINER CAPACITY

ASIC MINERS

9 Units

Housed at full load

POWER

50kw

Continuous electrical load

FORM FACTOR

Custom

Standard

COOLING

Hydro

Thermal management

AVAILABILITY       Contact us • DDP Sea Shipping Available

Compatible Models

Hydro Cooling Rack for Antminer Miners 9-Slot 50kW

The hydro cooling rack 9-slot is the most compact professional liquid cooling solution in our lineup, built for up to 9 Antminer S19, S21, or S23 Hydro units with a 50 kW thermal capacity. Paired with a matching dry cooler, it delivers organized, industrial-grade heat management in an 800 × 800 mm footprint — small enough for a garage corner, powerful enough for serious hashing.

Available in cooling and heating versions, the system adapts to your environment: the cooling version ensures stable heat removal year-round, while the heating version repurposes recovered heat for domestic space heating instead of letting it go to waste.

Built for homes and workshops, the rack centralizes every connection in one clean frame. It hashes reliably without industrial noise, keeping your workspace quiet, tidy, and professional.

Key Specifications at a Glance

  • Miner capacity: 9 Antminer Hydro units at full load
  • Cooling capacity: 50 kW continuous heat dissipation
  • Versions: Cooling or heating (heat recovery) configuration
  • Dimensions: 800 × 800 × 1,600 mm, just 155 kg
  • Ambient range: −25°C to 45°C with antifreeze coolant

Core Advantages

All-in-One Organized Design

The rack holds 9 miners while hiding all wiring and hoses inside the frame. It saves floor space in your garage and presents a clean, professional installation — not a pile of loose parts and tangled cables.

Ready-to-Use Color-Coded Connections

Aviation plugs and network cables come pre-configured for a fast setup. Blue connectors mark the water inlet and red connectors mark the outlet, so every miner is connected correctly the first time — no manuals required.

Reliable Water Pump System

Add coolant at the left inlet, flip the right switch, and the pump starts circulating. A fan rotation symbol on the back lets you verify flow direction at a glance — confirming normal circulation before your miners ever warm up.

Individual Power Safety Switches

Every miner has its own safety switch inside the rack. If one unit develops a power fault, only that switch trips — the rest of your 9 miners keep hashing, protecting your revenue from a full shutdown.

Optional Fan Speed Controller

An optional fan speed controller is available as a non-standard add-on. Manually balance cooling performance against noise levels to match your specific environment — ideal for installations in living spaces or shared buildings.

High-Efficiency Dry Cooler

The matching dry cooler exports heat from your facility efficiently. For high-temperature regions, an optional water curtain (wet pad) pre-chills the intake air before it reaches the coil, keeping hashrates stable through peak summer days.

Hydronic Heat Recovery Ready

The heating version turns your mining hardware into a heating system. The hydronic loop captures the 50 kW heat load and routes it where it is useful:

  • Versatile integration: supports underfloor heating, radiators, swimming pools, and other hydronic applications
  • Customizable options: heating modules tailored to your building layout and existing system
  • Energy reuse: repurpose mining-generated heat to reduce energy waste and lower overall heating costs

Hydro Cooling Rack 9-Slot

Full Technical Specifications

Model XON-H9 Installed capacity 9 seats
Heat dissipation capacity 50 kW Circulation mode Single mode / dual mode
Coolant Pure water / soft water + antifreeze + corrosion inhibitor Fluid flow rate 4 m³/h
Pump head 31 m Speed 2,900 r/min
Input / output voltage 3-phase 380–415V 50/60Hz Ambient temperature −25°C ~ 45°C
External dimensions 800 × 800 × 1,600 mm Internal dimensions 750 × 750 × 1,550 mm
Weight 155 kg Cooling configuration Rack + external dry cooler

Dry Cooler Specifications

Total Capacuty 50 kW Allowance 3-5% kW
Exchange Surface 1.28 ㎡ Coil Internal Volume 40± L
Design Pressure 0.3 MPa Woltage 30-400 V(±5%)
Dry Cooler Dimensions 1,100mm(L) * 1,100mm(W) * 1,400mm(H) Dry Cooler Weight 170 KG

Compatible Antminer Hydro Miners

The rack supports Antminer S19, S21, and S23 series hydro miners, including:

  • S19 series: S19 XP Hyd (257 Th/s · 20.6 J/Th), S19 Pro+ Hyd (198 Th/s · 27.5 J/Th), S19 XP+ Hyd (293 Th/s · 19 J/Th), S19e XP Hyd (251 Th/s · 22 J/Th)
  • S21 series: S21 Hydro (335 Th/s · 16 J/Th), S21 XP Hydro (473 Th/s · 12 J/Th), S21 XP+ Hyd (500 Th/s · 11 J/Th), S21+ Hydro (358 Th/s · 15 J/Th), S21e Hydro (310 Th/s · 17 J/Th), S21e XP Hyd (430 Th/s · 13 J/Th), S21j XP Hyd (495 Th/s · 12 J/Th)
  • S23 series: S23 Hyd (580 Th/s · 9.5 J/Th)

Keep the combined draw of your 9-unit configuration within the 50 kW system capacity for rated performance.

Scale Your Hydro Mining Infrastructure

The Hydro Cooling Rack 9-Slot is the compact entry point of the complete X-ON MINING liquid cooling product family:

Built to International Standards

X-ON MINING hydro cooling systems are manufactured to leading international standards for safety, reliability, and performance, including UL, CSA, CE, and China Classification Society (CCS) compliance — supporting smooth permitting and inspection in the US, Canada, and the EU.

Weight N/A
Dimensions N/A
Options

Hydro-Cooling + Heating Version, Hydro-Cooling Only Version(Dual Fans), Hydro-Cooling Only Version(Single Fan)

Reviews

There are no reviews yet.

Be the first to review “Antminer Hydro Cooling Rack 9-Slot 50kW”

This 9-slot 50kW hydro cooling rack is the most compact professional solution for Antminer hydro mining—all-in-one organized design, color-coded connections, individual safety switches, and optional heat recovery in an 800 × 800 mm footprint. For miners seeking industrial-grade liquid cooling in a garage-friendly package, this is the rack you’ve been waiting for.

Why Source This Rack From Us?

✅ Purpose-Built for Antminer Hydro – S19, S21, S23 series compatible
✅ Cooling or Heating Versions – Choose your configuration
✅ Color-Coded Connections – Fast, error-free setup
✅ International Certifications – UL, CSA, CE, CCS compliant
✅ Technical Support – Hydro cooling expertise at your service

Hydro Cooling Rack 9-Slot

FAQs

Yes. With an 800 × 800 mm footprint, 155 kg cabinet weight, and quiet operation, it is designed for professional home setups and garage operations where space and noise both matter.

Both versions cool your miners identically. The heating version adds heat recovery — it routes the 50 kW of mining heat to underfloor heating, radiators, or a pool instead of venting it outside, effectively reusing energy you have already paid for.

Every miner’s aviation plug and water line is pre-configured: blue connectors indicate the coolant inlet and red connectors indicate the outlet. Matching colors takes the guesswork out of installation and prevents reversed-flow mistakes.

Single mode runs one continuous coolant loop for straightforward home use. Dual mode separates the primary and secondary loops, which improves temperature stability and enables cleaner heat-recovery integration in the heating version.

Each miner is protected by its own safety switch. A fault trips only that unit’s switch, so the remaining eight miners keep hashing — no full-rack downtime while you resolve the issue.

In high-temperature regions, the optional water curtain (wet pad) pre-cools the air entering the dry cooler. Lower intake air temperature means stable coolant temperatures and consistent hashrates through peak summer afternoons.